VAL Avionics NAV 2000 Instalační příručka Strana 271

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 401
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 270
Accessory Installation and Configuration
SkyView System Installation Guide - Revision R 15-3
Heater Controller Module Physical Installation
Figure 92 shows the dimensions of the heater controller module.
Figure 92Heater Controller Module Dimensions
The heater controller module requires #6 mounting hardware and should ideally be mounted
close to the AOA/Pitot Probe. When mounting the controller close to the probe, ensure that it
is close enough for its wires to mate with the probe’s wires, with room for strain-relief. If you
find it difficult to mount the controller in the wing, or simply wish for the controller to be
mounted closer to the battery, you must extend the lines using the correct wire gauge as
described in Appendix C: Wiring and Electrical Connections.