Autopilot Servo Installation, Configuration, and Calibration
SkyView System Installation Guide - Revision R 10-11
Servo Electrical Installation
Dynon Avionics’ servos are supplied with 7 unterminated wires, each about 8” in length. We
recommended that you use the SV-NET-SERVO (one per servo) network cabling kit when
installing servos; however, it is ultimately the responsibility of the installer to decide on
connectors and associated wiring.
Table 42 describes servo wire colors and functions.
Color
Function
SV-NET-SERVO
D9 Pin
Notes
Red
Power
N/A
10 to 30 volts DC*
Black
Aircraft Ground
N/A
Can be locally grounded
Green
SkyView Network
Data 1 A
1
Connected in parallel with
other SkyView Network
devices
Blue
SkyView Network
Data 1 B
6
Connected in parallel with
other SkyView Network
devices
Yellow
AP
Disengage/Control
Wheel Steering
(CWS) Button
N/A
Connected through a
normally-open pushbutton
switch to Ground (disengages
AP when button is pushed). If
two servos are installed, the
yellow wire from each servo is
connected in parallel to a
single pushbutton.
White/Green
SkyView Network
Data 2 A
8
Connected in parallel with
other SkyView Network
devices
White/Blue
SkyView Network
Data 2 B
4
Connected in parallel with
other SkyView Network
devices
Table 42Detailed Servo Wiring
*Reference the